max_miss

QNX SDP8.0PLMS User's GuideAPIConfigurationDeveloper

Format

max_miss = number

Description

The max_miss keyword specifies the maximum number of consecutive heartbeats that can be missed before the component is declared to have failed. The heartbeat range is from 0 to INT_MAX(2147483647).

Default

The default number of heartbeats is 3.

Multiplicity

Zero or one instance in the monitor task block.