Synchronizing with the PCM subchannel

Updated: April 19, 2023

QSA provides some basic synchronization capabilities.

An application can find out where in the stream the hardware capture position is. The resolution of this position is entirely a function of the hardware driver; consult the specific device driver documentation for details if this is important to your application.

The API calls to get this information are:

Both of these functions fill in a snd_pcm_channel_status_t structure. You'll need to check the following members of this structure:

scount
The hardware capture position, in bytes relative to the start of the stream since you last prepared the channel. The act of preparing a channel resets this count.
count
The capture position as bytes in the PCM buffer.